Dynamic characteristics of high pressure low temperature economizer system when participating in load adjustment for double-reheat units
Thermal Power GenerationVol. 46, Issue 8, Pages: 77-81(2017)
更新时间:2025-05-30
分享给微信好友或者朋友圈
导出参考文献
Dynamic characteristics of high pressure low temperature economizer system when participating in load adjustment for double-reheat units
作者机构:
西安西热节能技术有限公司
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2017
稿件说明:
移动端阅览
CHANG Dongfeng, LUO Qing, FAN Qingwei, et al. Dynamic characteristics of high pressure low temperature economizer system when participating in load adjustment for double-reheat units[J]. Thermal Power Generation2017, 46(8): 77-81.
DOI:
CHANG Dongfeng, LUO Qing, FAN Qingwei, et al. Dynamic characteristics of high pressure low temperature economizer system when participating in load adjustment for double-reheat units[J]. Thermal Power Generation2017, 46(8): 77-81.DOI:
Dynamic characteristics of high pressure low temperature economizer system when participating in load adjustment for double-reheat units
摘要
针对二次再热机组高压低温省煤器(高省)参与负荷调节技术
对高省系统的动态影响特性进行模拟研究。结果表明:利用高省变流量调节负荷过程中
不同工况下机组负荷快速变化1%、2%和3%额定负荷时
高省出口水温变化幅度较小;相同负荷阶跃幅度下
机组初始运行负荷越高
高省出口水温响应速度越慢
到达稳定的时间越久;随着负荷调节量的增加
高省出口水温变化幅度增加
但对省煤器入口水温影响不大
对省煤器热冲击很小。本文研究成果可为配置高省系统的二次再热机组及一次再热机组进行快速变负荷技术改造
以及锅炉各类受热面在不同扰动下响应速率的预测提供参考。
Abstract
Against the partial HP preheater bypass technology(PHPHBT) used in high pressure low temperature economizer(HPLTE) system of double-reheat units
the dynamic characteristics of the HPLTE system were numerically studied. The results show that
the outlet water temperature variation of the HPLTE was small
when the unit load was changed by 1%
2% and 3% of the rated load rapidly under different working conditions with the adoption of PHPHBT. With the same load step
as the unit's initial load increased
the response speed of the water temperature at the HPLTE outlet slowed down
and the transition time it reached stable state prolonged. The variation of water temperature at the HPLTE outlet increased with the load adjustment value
but it rarely affected the water temperature at the economizer inlet. The above research fully demonstrated that the safety and stability of the relevant systems and equipment can be ensured after adopting the PHPHBT.