Mathematical modeling of intermediate point temperature for an ultra supercritical 1000MW unit once-through boiler
Thermal Power GenerationVol. 43, Issue 3, Pages: 21-25(2014)
更新时间:2025-09-28
分享给微信好友或者朋友圈
导出参考文献
Mathematical modeling of intermediate point temperature for an ultra supercritical 1000MW unit once-through boiler
作者机构:
1. 武汉大学动力与机械学院
2. 广东电网公司电力科学研究院
作者简介:
基金信息:
DOI:
CLC:TK229.2
Published:2014
稿件说明:
移动端阅览
FANG Yanjun, WANG Zhenyu, LI Xin, et al. Mathematical modeling of intermediate point temperature for an ultra supercritical 1000MW unit once-through boiler[J]. Thermal Power Generation, 2014, 43(3): 21-25.
DOI:
FANG Yanjun, WANG Zhenyu, LI Xin, et al. Mathematical modeling of intermediate point temperature for an ultra supercritical 1000MW unit once-through boiler[J]. Thermal Power Generation, 2014, 43(3): 21-25.DOI:
Mathematical modeling of intermediate point temperature for an ultra supercritical 1000MW unit once-through boiler
摘要
以东方锅炉股份有限公司制造的超超临界1 000MW机组锅炉为研究对象
根据质量守恒定律、能量守恒定律和金属热平衡定律
构建了与其相对应的中间点焓值机理模型。在建模过程中使用集中参数分多段的方法
经过线性化、偏差化处理得到了相应的传递函数
将该函数转化为矩阵形式。该模型能够反映直流锅炉中间点焓值在一定工况下的动态响应特性。
Abstract
Taking an ultra supercritical 1 000 MW unit boiler produced by Dongfang Boiler Co.
Ltd as the object
the intermediate point enthalpy mechanism model was established
according to the mass conservation principle
the energy conservation principle and the metal thermal equilibrium principle.During the modeling process
the lumped parameter segmentation method was employed.By linearization and deviation
the corresponding transfer function was obtained and finally transferred into matrix forms.This mechanism mathematical model can reflect the dynamic characteristics of the once-through boiler under research conditions to a certain extent.
MODELING OF SPRAY DESUPERHEATER IN AN ULTRA SUPERCRITICAL ONCE-THROUGH BOILER
Simulink based dynamic characteristics simulation for water wall on an ultra supercritical boiler
GMDH neural network based predictive modeling and simulation for superheated steam temperature of 1000MW ultra-supercritical units
Influence of heater on heat consumption rate of an ultra supercritical 1 000MW unit steam turbine
PRELIMINARY ANALYSIS OF REQUIREMENTS TO WATER-WALL SYSTEM PERFORMANCE FOR SERVICE OPERATION OF SUPERCRITICAL PRESSURE ONCETHROUGH BOILER OF 600MW UNITS
Related Author
WANG Zhenyu Department of Automation
CHANG Jingwei
TIAN Xiaoxuan
HUANG Jintao
CHEN Xiaoqiang
XU Xianzhen
CAI Lulu
ZHANG Jiangfeng
Related Institution
Xi'an Thermal Power Research Institute Co., Ltd
School of Energy and Power Engineering, Xi'an Jiaotong University
State Grid Zhejiang Electric Power Company Electric Power Science Research Institute
Institute of Intelligent Systems and Control, Zhejiang University
School of Electrical Engineering, Anhui University of Engineering