Evaluation methods for key performance indices of anti-corrosion coatings in FGD stacks
Thermal Power GenerationVol. 42, Issue 8, Pages: 150-152(2013)
更新时间:2025-09-28
分享给微信好友或者朋友圈
导出参考文献
Evaluation methods for key performance indices of anti-corrosion coatings in FGD stacks
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TM621.8
Published:2013
稿件说明:
移动端阅览
LI Haiyang, CAO Jieyu, QI Dongdong, et al. Evaluation methods for key performance indices of anti-corrosion coatings in FGD stacks[J]. Thermal Power Generation, 2013, 42(8): 150-152.
DOI:
LI Haiyang, CAO Jieyu, QI Dongdong, et al. Evaluation methods for key performance indices of anti-corrosion coatings in FGD stacks[J]. Thermal Power Generation, 2013, 42(8): 150-152.DOI:
Evaluation methods for key performance indices of anti-corrosion coatings in FGD stacks
The high-low temperature and dry-wet alternate runtime environment in the chimney after wet desulfurization is considered as the major reason for anti-corrosion coatings'failure.The existing problems of evaluation method for two key properties(adhesion and heat resistance performance)of the coating were analyzed.Measures such as using adhesion change between dry state and wet state and using the demineralized water soaking/high temperature baking cycling test to evaluate the anti-corrosion coating's ability for resisting the chimney's bad running environment were put forward.The test showed that the new detection method was more close to the actual situation
so it can evaluate the coating's performance accurately.