您当前的位置:
首页 >
文章列表页 >
DEBUGGING TEST OF COMBUSTION OPTIMIZATION AND RESULT ANALYSIS FOR ONE 1177t/h CFB BOILER
Thermal Power Generation   Vol. 41, Issue 1, Pages: 53-55(2012)
更新时间:2025-09-28
    • DEBUGGING TEST OF COMBUSTION OPTIMIZATION AND RESULT ANALYSIS FOR ONE 1177t/h CFB BOILER

    • CLC: TK229.6
    • Published:2012

    移动端阅览

  • YANG Yong1, LIU Haifeng2, WANG Haitao2, et al. DEBUGGING TEST OF COMBUSTION OPTIMIZATION AND RESULT ANALYSIS FOR ONE 1177t/h CFB BOILER[J]. Thermal Power Generation, 2012, 41(1): 53-55. DOI:

  •  
  •  
icon
试读结束,您可以激活您的VIP账号继续阅读。
去激活 >
icon
试读结束,您可以通过登录账户,到个人中心,购买VIP会员阅读全文。
已是VIP会员?
去登录 >

0

Views

126

下载量

8

CSCD

Alert me when the article has been cited
提交
Outline
No Sections

Related Articles

Experimental study on combustion and emission characteristics of a supercritical 600 MW unit CFB boiler firing different coals
The optimal static regulation characteristics of circulating fluidized bed boiler based on combustion optimization
Low-NOx combustion retrofitting and optimal adjustment tests for a 130 t/h CFB boiler
DESIGN AND OPERATION OF 480 t/h CFB BOILER
MATHEMATICAL MODEL AND PREVENTIVE MEASURES OF WEAR-OUT IN CFB BOILERS

Related Author

JIN Senwang
GAO Hongpei
SUN Xianbin
SHI Zhenghai
XIAO Ping
LI Yuzhe
TANG Jun
XIE Zeliang

Related Institution

China Huaneng Clean Energy Research Institute Co., Ltd.
Sichuan Baima CFB Demonstration Power Plant Co., Ltd.
Shanxi Electric Power Research Institute, Shanxi Electric Power Corporation
College of Electrical & Power Engineering, Taiyuan University of Technology
State Key Laboratory of Clean Energy Utilization, Zhejiang University
0