您当前的位置:
首页 >
文章列表页 >
CAUSE ANALYSIS OF TUBE-BURST IN FINAL-STAGE SUPERHEATER OF BOILER EQUIPPED FOR SUPERCRITICAL 600 MW UNIT AND PREVENTIVE MEASURES THEREOF
Thermal Power Generation   Vol. 40, Issue 7, Pages: 81-83(2011)
更新时间:2025-09-28
    • CAUSE ANALYSIS OF TUBE-BURST IN FINAL-STAGE SUPERHEATER OF BOILER EQUIPPED FOR SUPERCRITICAL 600 MW UNIT AND PREVENTIVE MEASURES THEREOF

    • CLC: TK223.32
    • Published:2011

    移动端阅览

  • CHENG Zhihong Guangdong Zhuhai Jinwan Power Generation Co Ltd. CAUSE ANALYSIS OF TUBE-BURST IN FINAL-STAGE SUPERHEATER OF BOILER EQUIPPED FOR SUPERCRITICAL 600 MW UNIT AND PREVENTIVE MEASURES THEREOF[J]. Thermal Power Generation, 2011, 40(7): 81-83. DOI:

  •  
  •  
icon
试读结束,您可以激活您的VIP账号继续阅读。
去激活 >
icon
试读结束,您可以通过登录账户,到个人中心,购买VIP会员阅读全文。
已是VIP会员?
去登录 >

0

Views

167

下载量

16

CSCD

Alert me when the article has been cited
提交
Outline
No Sections

Related Articles

Application of treatment technology for oxide scale on superheaters
CAUSES LEADING TO OVER-TEMPERATURE OF SUPERHEATER FOR BOILERS OF SUPERCRITICAL 600MW UNITS AT INITIAL STAGE OF START-UP AND CONTROL THEREOF
CAUSE ANALYSIS OF SPACING TUBE BURST ON PLATEN SUPERHEATER OF ONE SUPERCRITICAL BOILER AND COUNTERMEASURES THEREOF
CONTROL OF MAIN STEAM TEMPERATURE FOR SUPERCRITICAL 600 MW UNIT EQUIPED WITH DOUBLE-INLET AND DOUBLE-OUTLET COAL PULVERIZER
CONTROL MEASURES FROM BOILER SIDE IN LOAD REJECTION TEST OF SUPERCRITICAL 600 MW UNIT

Related Author

GAN Chaoqi
CHEN Xing
LI Hong-pingXinyang Huayu Power Generation Co Ltd
WEN Zhi-hua1
SHANG Hai-jun2
YANG Hang-bing11.Huaneng Reijin Power Plant
ZHAO Zhi-dan1
CHEN Zhi-gang1

Related Institution

Hebei Guohua Dingzhou Power Generation Co.,Ltd.,Dingzhou
Datang Xinyang Huayu Power Generation Co., Ltd
Huaneng Ruijin Power Plant
Xi'an Thermal Power Research Institute Co., Ltd
Huaneng Qinbei Power Generation Co., Ltd
0