ANALYSIS OF CLAMPING TUBE LEAKAGE FOR REAR PLATEN SUPERHEATER OF THE BOILER
The causes of clamping tube leakage for rear platen superheater of a 2 045 t/h boiler in one power plant have been analysed by using methods of macroscopic inspection
crack analysis
chemical elements analysis
tensile strength analysis
microscopic hardness test
metallographic structure analysis
intergranular corrosion test
etc..The results show that the clamping tube leakage of rear platen superheater is caused by intergranular corrosion cracking on the steam side.Firstly the intergranular corrosion cracks happened at inner wall of middle profile in elow of the clamping tube