CAUSE ANALYSIS OF SLAGGING IN A 440 t/h CFB BOILER AND COUNTERMEASURES THEREOF
Thermal Power Generation   Issue 8, Pages: 58-60(2007)
更新时间:2025-09-28
    • CAUSE ANALYSIS OF SLAGGING IN A 440 t/h CFB BOILER AND COUNTERMEASURES THEREOF

    • DOI:10.19666/j.rlfd.2007.08.030    

      CLC: TK227.2
    • Published:2007

    移动端阅览

  • QIN Guang-ming1, LIU Jia-ping21.Shaoguan Power Plant. CAUSE ANALYSIS OF SLAGGING IN A 440 t/h CFB BOILER AND COUNTERMEASURES THEREOF[J]. Thermal Power Generation, 2007, (8): 58-60. DOI: 10.19666/j.rlfd.2007.08.030.

  •  
  •  
icon
试读结束,您可以激活您的VIP账号继续阅读。
去激活 >
icon
试读结束,您可以通过登录账户,到个人中心,购买VIP会员阅读全文。
已是VIP会员?
去登录 >

0

Views

81

下载量

1

CSCD

Alert me when the article has been cited
提交
Outline
No Sections

Related Articles

Experimental study on coal slime co-firing in a supercritical 600 MW CFB boiler
Experimental study on uniformity of air distribution in a subcritical 300 MW circulating fluidized bed boiler
CLOSED-LOOP CONTROL SYSTEM OF CFB BOILERS
OPERATION PRACTICE OF CANADAMADE BW1190t/h BOILER AND STUDY ON COUNTEMEASURES FOR PERFORMANCE IMPROVEMENT THEREOF
PREVENTION OF SLAGGING IN BOILERS AND RETROFITTING HORIZONTARL RICH/LEAN BURNERS THEREOF

Related Author

LU Rongchun
RU Yu
LI Jiyun
ZHAO Pengbo
GAO Hongpei
SUN Xianbin
WANG Haitao
WANG Quanhai

Related Institution

Shenhua (Fujian) Energy Co., Ltd
State Key Laboratory of Coal based Clean Energy of China Huaneng Group Clean Energy Technology Research Institute Co., Ltd
Shaanxi Jingyi Chemical Co., Ltd
Key Laboratory of Low Grade Energy Utilization Technology and Systems, Ministry of Education, Chongqing University
Datang Wu'an Power Generation Co., Ltd
0