AN Jihua, MA Qinghua, ZHANG Yifan, et al. Thermal hydrodynamic characteristics and wall temperature distribution of an ultra-supercritical 1 000 MW unit double-reheat tower type boiler[J]. Thermal Power Generation2018, 47(12): 134-140.
DOI:
AN Jihua, MA Qinghua, ZHANG Yifan, et al. Thermal hydrodynamic characteristics and wall temperature distribution of an ultra-supercritical 1 000 MW unit double-reheat tower type boiler[J]. Thermal Power Generation2018, 47(12): 134-140. DOI: 10.19666/j.rlfd.201805118.
Thermal hydrodynamic characteristics and wall temperature distribution of an ultra-supercritical 1 000 MW unit double-reheat tower type boiler
The working parameters of ultra-supercritical double-reheat boilers are high
making the working environment of water wall more harsh
which puts forward higher requirements for hydrodynamic power of the boiler. In this paper
the ultra-supercritical 1 000 MW double-reheat tower type boiler in Huaneng Laiwu Power Generation Co.
Ltd. is taken as an example for the detailed thermal hydrodynamic research. Based on data from both field measurement and theoretical calculation
thermal hydrodynamic characteristics and wall temperature distributions are analyzed
under BMCR
75%BMCR
50%BMCR
35%BMCR condition. The results show that
the deviations of both mass flow rate and wall temperature decrease by using the spiral tube water wall in the lower furnace. Although there is somewhat deviation of mass flow rate in the vertical upward water wall
the wall temperature distribution is still in a reasonable region
due to a large scale of convective heat transfer area in the higher furnace.