ZHONG Yiqing, SUN Yangyang, YAO Guopeng, et al. Application of condensation water throttling technology in flexibility transformation of coal-fired units[J]. Thermal Power Generation2018, 47(12): 77-81.
DOI:
ZHONG Yiqing, SUN Yangyang, YAO Guopeng, et al. Application of condensation water throttling technology in flexibility transformation of coal-fired units[J]. Thermal Power Generation2018, 47(12): 77-81. DOI: 10.19666/j.rlfd.201805141.
Application of condensation water throttling technology in flexibility transformation of coal-fired units
Four strategies for improving the flexibility of coal-fired units are introduced in detail
which are coordinated control frequency modulation(FM) based on advanced control technology
throttle frequency modulation in condensate water
short-term FM of heating unit
and FM in condenser's back pressure. Combined with the actual work
the condensation water throttle fast load technology is integrated with the original coordinated control of a power plant. After the project is implemented
the whole system runs steadily. The unit load can quickly respond to the change of AGC instruction
only the condensation water throttling can increase the load regulation rate by 1.6%Pe/min
and AGC adjustment dead zone can be quickly stepped out within 25 s
the regulation performance is good. According to the calculation
the comprehensive index of the average adjustment performance of the unit has been improved by about 10%
the coal consumption is reduced by about 0.93 g/(kW·h)
and the economy and peak regulating capacity of the unit are further improved.