MAO Kaiyuan, NIE Xin, XIE Haiyan, et al. Computational analysis on hydrodynamic characteristics and flow instability of an ultra supercritical 1 000 MW double-reheat unit boiler[J]. Thermal Power Generation2017, 46(8): 36-41.
MAO Kaiyuan, NIE Xin, XIE Haiyan, et al. Computational analysis on hydrodynamic characteristics and flow instability of an ultra supercritical 1 000 MW double-reheat unit boiler[J]. Thermal Power Generation2017, 46(8): 36-41.DOI:
The ultra supercritical 1 000 MW unit boiler with double-reheat cycle in Datang Leizhou Power Plant adopts Π type arrangement. Due to the complexity of water flow in Π type boiler
there exists the risk of uneven distribution of mass flow rate
which may result in the water wall overheat accident. In the processes of unit wide load operation and fast peak shaving
flow instability may occur in the water wall of the boiler due to the coal supply disturbance. To solve these problems
the distributions of mass flow rate
working fluid and metal temperatures in water wall at BMCR load were calculated by flow network system method
and the flow instability was checked for 30%THA load. On this basis
the optimal design and safe operation of the water wall were analyzed. The calculation results show that the water wall can avoid excessive stress between pipes and tension crack. The mass flow rate can finally restore stability after being disturbed by heat load. The water wall is safe and reliable.