福斯特惠勒高压加热器故障处理
摘要
对上安电厂6号高压加热器汽侧壳体故障原因进行了分析。在其故障停运期间
采取临时技术措施
使其它高压加热器继续运行。对6号高压加热器故障损坏修复和高压加热器的运行方式提出了建议。
Abstract
The causes leading to failure of steam side shell of high-pressure(HP) heater no.6 in Shang'an Power Plant has been analysed
in shutdown time of the said failurd HP heater
other HP heaters are maintained in operation by adopting temporary technical measures
avoiding serious economic loss of the units and recommodations for the repair work of HP heater no.6 and operation mode of the HP heaters have been put forward.