Through summary analysis on operation data of several units' denitration system
this paper points out that there are differences in ammonia escape at outlet of the denitration equipments in different combustion modes and operation control modes. As a result
there is obvious difference in ammonium bisulfate(ABS) plugging in downstream equipments like the air preheater
indicating it is necessary and important to optimize the whole process from the aspects of boiler combustion
denitration equipment
and flue gas flow and mixing. To solve the secondary problem like the ABS blockage in air preheater after ultra-low emission retrofitting of the denitration system
it is suggested that the whole process management concept be adopted to control ammonia escape from the source and improve the operation level of the denitration system.