ZHOU Changxin, LIU Jianquan, WU Zhenxin, et al. Numerical simulation of thermal deviation of 700 ℃ tangentially fired boiler based on orthogonal test method[J]. Thermal Power Generation, 2022, 51(2): 150-156.
ZHOU Changxin, LIU Jianquan, WU Zhenxin, et al. Numerical simulation of thermal deviation of 700 ℃ tangentially fired boiler based on orthogonal test method[J]. Thermal Power Generation, 2022, 51(2): 150-156. DOI: 10.19666/j.rlfd.202105098.
In order to solve the problem of large thermal deviation of 700 ℃ tangentially fired boiler
numerical simulation is carried out by using Fluent 16.0 software. With thermal deviation of furnace outlet section as the optimization index
three factors
such as anti-tangential angle of over fire air(factor A)
velocity offset of over fire air(factor B)
and the interaction between factor A and B(factor A×B)
are optimized at three levels. Range analysis method and weight matrix analysis method are applied to determine the best combination of the above three factors and levels and the specific weight proportion. The results show that
the importance degree of each factor to the thermal deviation of the outlet section of the furnace is as follows: anti-tangential angle of over fire air over fire air velocity offset the interaction between anti-tangential angle of over fire air and over fire air velocity offset.The weight proportions of factor A
factor B and factor A×B is 0.875
0.079
and 0.046. Through two analysis methods
it is concluded that the interaction between anti-tangential angle of over fire air and over fire air velocity offset can be neglected. The best factor and horizontal combination of the orthogonal test is A3B3. In this combination scheme
the anti-tangential angle of over fire air is 25°
the over fire air speed ratio(right side/left side)is 0.77
and the thermal deviation of the outlet section of the combined furnace is 28.405 K
which is 89.01 K lower than the highest thermal deviation